What different FAAC 402 model variants are available (e.g., CBC vs SBS) and what’s the difference between them?
▼
The FAAC 402 hydraulic swing gate operator is available in three variants: CBC, SB, and SBS. The primary differences are whether the operator hydraulically locks the gate, operating speed, and the maximum gate leaf size it is designed to handle.
• The CBC (Closing Blocking/Close Lock) version includes an internal hydraulic lock in the closed position.
• The SB version is a reversible (non-locking) operator.
• The SBS version is also non-locking, but is designed specifically for larger gates.
How do I adjust the hydraulic bypass pressure for opening and closing force?
▼
Force adjustment is done using the two bypass valves located on the operator body. One controls opening force and the other controls closing force. Turning the valves clockwise increases force, while counterclockwise decreases force. Adjustments should be made gradually and tested repeatedly to ensure safe operation and compliance with safety standards.
What accessories (photocells, loop detectors, electric locks) can be connected to the 402 control panel?
▼
The control board accepts a variety of activation devices, including:
• Radio receiver modules
• Handheld remote transmitters
• Wireless keypads (through the receiver)
• Hardwired key-operated switches
• Push buttons
• Telephone entry systems
• Intercom systems
• Fire department override switches
• Hold-open devices
These devices connect to the board's command inputs and can initiate gate opening or hold the gate open as required.
How do I interpret the control panel status lights or indicators on the 402 system?
▼
On a FAAC 402 swing gate system, the status indicators are normally located on the FAAC 455 D control board (the controller commonly paired with 402 hydraulic operators). The board uses a two-digit LED display made up of segments to show the condition of the command inputs, safety circuits, and limit switches.
A key rule for interpreting the display:
LED segment ON = the input circuit is closed (normal/active depending on the input)
LED segment OFF = the input circuit is open or triggered
What are the recommended maintenance intervals and tasks for the FAAC 402 hydraulic unit?
▼
An annual check requires:
• Inspect gate hinges and movement
• Verify hydraulic oil level
• Check bypass pressure adjustments
• Test photocells and safety devices
• Test manual release
• Inspect mounting hardware
• Check for hydraulic leaks
• Clean control panel enclosure
• Verify smooth opening and closing cycles
Following this schedule helps maintain the FAAC 402’s hydraulic performance, safety operation, and long service life.
Is the FAAC 402 suitable for both inward and outward swing gate installations?
▼
Yes. The FAAC 402 hydraulic operator is suitable for both inward-swinging and outward-swinging gate installations. The operator itself does not require a different model for swing direction; the difference is in the mounting geometry and piston positioning during installation.
For a gate that swings into the property (toward the driveway):
• Place the gate in the fully closed position against the closing stop.
• Manually release the hydraulic operator.
• Extend the piston completely outward.
• Push the piston back inward approximately ¼ inch (6 mm).
• Attach and align the front mounting bracket.
For a gate that swings out toward the street or outside the property:
• Place the gate in the fully closed position.
• Manually release the operator.
• Retract the piston completely inward.
• Pull the piston back out approximately ¼ inch (6 mm).
• Mount the front bracket using the correct outward-swing dimensions.
How do I check and maintain the hydraulic oil level in the 402 operator?
▼
To check the oil level correctly, remove the operator from the gate leaf. With the piston rod completely retracted and pointing to the ground, remove the rear flange and look at the oil level in the casing of the operator. To maintain oil level, change the oil every 2 years if the operator is used heavily. If the operator is used lightly, change the oil every 4 years.
What safety signage and installation clearances are required for safe operation?
▼
The FAAC 402 system requires permanent warning signs installed on both sides of the gate to alert pedestrians and vehicles of automated operation. Adequate clearance must be maintained so the gate does not contact fixed structures during movement. Control devices should be installed at least 6 ft (1.8 m) away from moving gate components. Proper grounding and separation of high/low voltage wiring are also required for safety compliance.
What hydraulic features (like anti-crushing bypass valves) does the 402 use and how do they work?
▼
The 402 Operator also includes a triangular key operated Manual Release Mechanism and two bypass valves which precisely control the force applied to the gate leave(s). The Manual Release Mechanism is a key operated device that disengages or engages the hydraulic system of the 402 Operator. When the hydraulic system is disengaged, you can open and close the gate leaf by hand.