FAAC Model 402 Hydraulic Single Swing Gate Operator



Contract Price: $2,004.99
Original Price: $2,390.00
Price: $2,004.99
In Stock
Quantity:


bookmark this pageSave this page

Chat with a live representative or Send us an email

1-800-537-4283
Quick Content Anchors
Popular DIY Packages
Deer Protection Package
Subtotal for(4) items
$596.95 Add to Cart >
Authorized Entrance / Communication Package
Subtotal for(3) items
$897.95 Add to Cart >
Limited Access / Full Security Package
Subtotal for(3) items
$328.98 Add to Cart >
Exit Convenience Package
Subtotal for(3) items
$338.94 Add to Cart >
Safety Package
Subtotal for(4) items
$458.89 Add to Cart >
Subtotal for(4) items
$596.95
Add to Cart >
Subtotal for(3) items
$897.95
Add to Cart >
Subtotal for(3) items
$328.98
Add to Cart >
Subtotal for(3) items
$338.94
Add to Cart >
Subtotal for(4) items
$458.89
Add to Cart >
   Gate Operator at a Glance Top of Page

Hydraulic gate openers are stronger and more reliable than electromechanical gate openers, and are therefore trusted more. They offer many advantages that make them superior and preferable over electromechanical gate openers.

  • Weight and length: Up to 12 feet or 900 lbs per leaf
  • Solar Compatible: No
  • Input Voltage: 115 VAC or 230VAC
  • Operating Temperature: -33℉ to 165℉ (-36℃ to +74℃)
  • Cycles per hour: 55 cycles
  • Warranty: 2 year manufacturer warranty

Designed for basic single family residential use

Gate Crafters offers more expert assistance than anyone. If you need help deciding if this gate operator has the abilities that are right for your gate we have live application specialists available 9am - 9 pm EST 7 days a week or try our exclusive gate operator recommendation tool 24 hours/day.

   Gate Operator Description Top of Page

FAAC 402 Hydraulic Swing Gate Operator

FAAC standard (CBCR) 402 hydraulic swing gate operator is specifically designed for situations needing maximum versatility, such as certain apartment, subdivision, commercial/industrial, residential applications and in situations that have very limited or tight places. It can accommodate gates up to 900lbs and 12’ feet length, an excellent choice for large ornament gates.

Hydraulic gate operators are inherently safer than other types of operators because they do not have "pinch points". This unit can be used to swing the gate leaf inward or outward. In addition, FAAC operators are equipped with a hydraulic bypass valve for extra anti-entrapment protection, and a manual release that allows the gate to be operated in an emergency, such as power failure. A battery back-up unit is also available.

The electronic control panel is a microprocessor-based controller that accepts a wide range of products accessories and reversing devices thus allowing flexible gate system design. FAAC 402 standard can hydraulically lock your gate in your choice of opened and/or closed positions. Your gate system will also be set up to provide special options, including "gate-safe" and "gate-secure" configurations:

- Gate-safe: during power outages, a magnetic lock releases a closed gate to allow emergency access.

- Gate-secure: during power outages, an electric lock keeps the gate locked.

NOTE: For its protection, the single-phase bidirectional motor shuts off automatically if its operating temperature reaches 212 deg F (100 deg C). Also for the protection and proper operation each gate leaf on which it is installed must have a fixed positive stop in both the opened and close positions. To guarantee the safety and efficiency of its equipment, FAAC strongly recommends that qualified personnel test the safety system on an annual basis, as well as maintain the overall hydraulic or mechanical system.


   Gate Operator Features and Specifications Top of Page
Features
  • Versatile hydraulic operator for residential and light commercial applications
  • Key protected manual release
  • Quiet operation
  • Self lubricating
  • UL 325 Compliant
  • Long lasting anodized aluminum casing
Specifications
  • Model: Hydraulic Swing Gate Operator 402
  • Input Voltage: 115 VAC or 230 VAC
  • Type of oil: Lubrication-Engineers - Monolec 6105
  • 90° Opening Time: Approx. 12 seconds
  • Leaf Maximum Width: 12 ft. (3.6)
  • Leaf Maximum Weight: 900 lb (410Kg)
  • Max Cycles Per Hour: 55
  • Warranty: 2 years
What's in the box
  • 1 Operator 402 CBAC (2 for dual application)
  • 1 455D control panel 115V
  • 1 433 RC Plug-in Receiver
  • 2 Transmitters
  • 1 Pair of FAAC Photocells
  • 1 14" x 16" Enclosure
GateCrafters.com has the resources you need. How do you use your gate operator system once you get it? GateCrafters.com is the only retailer to give a real answer to this question. We have developed videos for installing many of our gate operators and products and write DIY focused manuals for most gate operators and have individual instructions for each accessory to be installed with each gate operator.

   Gate Crafters Exclusive Additions Top of Page
  • Free 24/7/365 Installation Support
  • Free 7 day/week Technical Support
  • Largest Number of Certified Techs in America
  • Free assistance to find the right gate operator for your gate
  • Free systems design assistance to match the right accessories to fit your needs.
  • Extremely competitive pricing
  • Free shipping on all accessories purchased with a gate operator
  • We stock replacement parts
  • Many brands of many types of accessories, enough to handle just about any operational situation you can imagine
Gate Crafters has actual experience. We have a testing area, we have factory and internal training courses, we build gates and have our own gates that are automated, we attended all industry trade shows in multiple countries and are a member of the AFA, and we pay visits to our chosen manufacturers' factories. All These factors are what have lead to us having so many exclusive additions. When you see and actually use as many products as we have you tend to have many ideas for minor changes that have major impacts. We acted on these ideas and have utilized them to help thousands of customers automate their gates.
   Tools & Supplies for Installation Top of Page

The following tools and supplies are suggested in the manufacturer manual for optimal installation. They are not provided by Gate Crafters, however, most tools are available at local hardware stores for purchase or rental.

Depending on the type of gate, power supply and contributing environmental factors additional tools or supplies may be needed. Please review the product manual associated with this gate operator model for further details.

   Product Media Top of Page


Manual: FAAC 402
QB ID: 1044682.5*

   Dynmaic FAQ
What different FAAC 402 model variants are available (e.g., CBC vs SBS) and what’s the difference between them? ▼
The FAAC 402 hydraulic swing gate operator is available in three variants: CBC, SB, and SBS. The primary differences are whether the operator hydraulically locks the gate, operating speed, and the maximum gate leaf size it is designed to handle. • The CBC (Closing Blocking/Close Lock) version includes an internal hydraulic lock in the closed position. • The SB version is a reversible (non-locking) operator. • The SBS version is also non-locking, but is designed specifically for larger gates.
How do I adjust the hydraulic bypass pressure for opening and closing force? ▼
Force adjustment is done using the two bypass valves located on the operator body. One controls opening force and the other controls closing force. Turning the valves clockwise increases force, while counterclockwise decreases force. Adjustments should be made gradually and tested repeatedly to ensure safe operation and compliance with safety standards.
What accessories (photocells, loop detectors, electric locks) can be connected to the 402 control panel? ▼
The control board accepts a variety of activation devices, including: • Radio receiver modules • Handheld remote transmitters • Wireless keypads (through the receiver) • Hardwired key-operated switches • Push buttons • Telephone entry systems • Intercom systems • Fire department override switches • Hold-open devices These devices connect to the board's command inputs and can initiate gate opening or hold the gate open as required.
How do I interpret the control panel status lights or indicators on the 402 system? ▼
On a FAAC 402 swing gate system, the status indicators are normally located on the FAAC 455 D control board (the controller commonly paired with 402 hydraulic operators). The board uses a two-digit LED display made up of segments to show the condition of the command inputs, safety circuits, and limit switches. A key rule for interpreting the display: LED segment ON = the input circuit is closed (normal/active depending on the input) LED segment OFF = the input circuit is open or triggered
What are the recommended maintenance intervals and tasks for the FAAC 402 hydraulic unit? ▼
An annual check requires: • Inspect gate hinges and movement • Verify hydraulic oil level • Check bypass pressure adjustments • Test photocells and safety devices • Test manual release • Inspect mounting hardware • Check for hydraulic leaks • Clean control panel enclosure • Verify smooth opening and closing cycles Following this schedule helps maintain the FAAC 402’s hydraulic performance, safety operation, and long service life.
Is the FAAC 402 suitable for both inward and outward swing gate installations? ▼
Yes. The FAAC 402 hydraulic operator is suitable for both inward-swinging and outward-swinging gate installations. The operator itself does not require a different model for swing direction; the difference is in the mounting geometry and piston positioning during installation. For a gate that swings into the property (toward the driveway): • Place the gate in the fully closed position against the closing stop. • Manually release the hydraulic operator. • Extend the piston completely outward. • Push the piston back inward approximately ¼ inch (6 mm). • Attach and align the front mounting bracket. For a gate that swings out toward the street or outside the property: • Place the gate in the fully closed position. • Manually release the operator. • Retract the piston completely inward. • Pull the piston back out approximately ¼ inch (6 mm). • Mount the front bracket using the correct outward-swing dimensions.
How do I check and maintain the hydraulic oil level in the 402 operator? ▼
To check the oil level correctly, remove the operator from the gate leaf. With the piston rod completely retracted and pointing to the ground, remove the rear flange and look at the oil level in the casing of the operator. To maintain oil level, change the oil every 2 years if the operator is used heavily. If the operator is used lightly, change the oil every 4 years.
What safety signage and installation clearances are required for safe operation? ▼
The FAAC 402 system requires permanent warning signs installed on both sides of the gate to alert pedestrians and vehicles of automated operation. Adequate clearance must be maintained so the gate does not contact fixed structures during movement. Control devices should be installed at least 6 ft (1.8 m) away from moving gate components. Proper grounding and separation of high/low voltage wiring are also required for safety compliance.
What hydraulic features (like anti-crushing bypass valves) does the 402 use and how do they work? ▼
The 402 Operator also includes a triangular key operated Manual Release Mechanism and two bypass valves which precisely control the force applied to the gate leave(s). The Manual Release Mechanism is a key operated device that disengages or engages the hydraulic system of the 402 Operator. When the hydraulic system is disengaged, you can open and close the gate leaf by hand.