What safety and entrapment protection devices are required to meet UL 325 compliance?
▼
• A minimum of two independent monitored entrapment protection devices are required to be installed at each entrapment zone.
• It is the responsibility of the installer to install external monitored entrapment protection devices for each entrapment zone
• The operator will only operate with a minimum of two independent monitored entrapment protection devices installed in either the open or closed direction. If no entrapment zone exists in the other direction, an external entrapment protection device is NOT required in that direction.
• This operator has an inherent entrapment protection device built-in. The installer MUST provide one additional entrapment protection device for each entrapment zone
How do I adjust the gate’s opening speed, closing speed, and other motion parameters?
▼
• The factory setting is minimum speed.
• Turn the dial to increase or decrease the overall gate travel speed.
• The operator supports a 90° travel time of approximately 13 to 36 seconds, depending on the arm configuration.
• Use the lowest speed that provides reliable operation, as higher speeds increase the risk to pedestrians.
• On dual-gate systems, set both operators to the same speed, or make the gate that closes first slightly faster for smoother synchronized operation.
What maintenance is required to ensure long-term reliable operation?
▼
• Inspect the gate for smooth, balanced movement. The gate should swing freely without binding or excessive resistance.
• Check all mounting hardware on the operator, gate brackets, and hinges, and tighten any loose fasteners.
• Inspect the operator arm and pivot points for wear or damage.
• Test all entrapment protection devices, including monitored photo eyes and edge sensors, to verify the gate stops and reverses correctly when activated.
• Verify the manual disconnect operates properly and can be re-engaged securely after use.
• Check the warning signs and replace any that are damaged or no longer legible.
What accessories and options are supported and how do they work?
▼
• Remote Controls
• Keyless Entry
• Wireless commercial keypad
• Liftmaster Internet Gateway
• Loop Detectors
• Post-mounting plate
• Remote antenna extension kit
These accessories are used to ensure you get the most out of your gate operator. They work to ensure safety and proper operation of the gate.
What is included in the HDSW24UL gate operator kit?
▼
• HDSW24UL heavy-duty swing gate operator (motor/gearbox assembly)
• Integrated control box with the main control board
• Two 12 V, 7 Ah batteries (24 VDC battery backup system)
• Mounting hardware and brackets for installing the operator
• Gate arm and connection hardware
• Manual disconnect mechanism for emergency manual operation
• Installation manual and wiring documentation
• Warning signs required for UL 325-compliant installations
How do I manually release or operate the gate during a power outage?
▼
To manually release the gate:
• Stop gate operation
• Set the reset switch to the RESET position.
• Remove the top (cludge) cover.
• Rotate the manual disconnect handle 180°
• Move the gate manually
To return the operator to normal:
• Move the gate to a suitable position.
• Rotate the manual disconnect handle back to its original position and push it down to fully re-engage the drive.
• Set the reset switch back to NORMAL OPERATION.
• Reinstall and secure the top cover.
• Test the operator to verify the gate opens and closes normally.
Why won’t the gate open or close when commanded by the remote or control input?
▼
1. Activate wireless control and check XMITTER LED is on. Re-learn wireless control/transmitter to control board. Replace wireless control as needed.
2. Set reset switch to NORMAL OPERATION
3. Check if similar wired control operates correctly. Check if wireless controls work properly when within a few feet of the operator. Check the operator's antenna and antenna wire. Check other wireless controls or devices.
Why does the gate stop, reverse, or behave unexpectedly during operation?
▼
• Check all open and close inputs for an active input
• Check all vehicle detector inputs for an active detector
• Battery voltage must be 23 Vdc or higher. Charge batteries by AC or solar power or replace batteries
• If there are no obstructions in gate path, manually disconnect the gate, and ensure it moves easily limit to limit. Repair gate as needed.
How do I troubleshoot diagnostic LED indicators and error codes on the control board?
▼
• Code 31 - Main Control board has experienced an internal failure. Disconnect all power, wait 15 seconds, then reconnect power (reboot). If issue continues, replace main control board
• Code 40 - Battery overvoltage. Too much voltage on the battery. Check harnesses. Make sure there is NOT a 24V battery on a 12V system.
• Code 42 - No battery at boot up. Check battery connections and installation. Replace batteries if depleted to less than 20V on a 24V system or less than 10V on a 12V system. Make sure there is NOT a single 12V battery on a 24V system
• Code 46 - Wireless edge battery low. Replace Batteries in wireless edge.
For the full list of diagnostic codes, refer to the manual for more specific problems.
What type of power supply does this operator require?
▼
The main AC Supply for this operator is 120V and 4 Amps, or 240V and 2 Amps. A 24 VDC battery system (two 12 V batteries wired in series) is used for backup operation during AC power loss and is kept charged by the built-in charger.
How do I install the HDSW24UL swing gate operator?
▼
1. Determine Location for Concrete Pad and Operator
2. Install the concrete pad
3, Mount the operator
4. Attach the gate bracket and operator arm
5. Install required entrapment protection
6. Install an earth ground
7. Connect power and wiring
8. Program and adjust the operator
9. Install the covers and warning signs
10. Test the complete system
How do I program or pair remote controls and access devices with this system?
▼
The LiftMaster HDSW24UL uses a built-in Security+ 2.0® radio receiver and can store up to 50 Security+ 2.0 remote controls or KPW250 wireless keypads, plus 2 wireless keyless entries. To program them:
• Press and release the LEARN button on the control board. The operator beeps and the green XMITTER LED lights.
• Within 30 seconds, press the OPEN button on the control board.
• Press the desired button on the remote control.
• The operator beeps and exits programming mode when the remote has been learned successfully.
Is the HDSW24UL compatible with myQ® smart control and how do I set it up?
▼
To program the operator to the LiftMaster Internet Gateway:
1.Connect the ethernet cable to the LiftMaster Internet Gateway and the router.
2.Connect power to the LiftMaster Internet Gateway.
3.Download the myQ® App.
4.Set up an account and follow the app instructions to add your gate operator.
5.The LiftMaster Internet Gateway will pair to the operator if it is within range and the operator will beep if programming is successful.
The gate operator can then be controlled through the myQ®App.
What maximum gate weight and length can the HDSW24UL support?
▼
The maximum gate weight the HDSW24UL can support is 2800 lbs and the max size it can support is 22 ft.
Can this operator be integrated with additional access systems?
▼
Yes. There are external control devices such as exit probes, telephone entry, external exit loop detectors, or any device that would command the gate to open. These devices can be connected using the control board.